Order specifications: Push-in RTD temperature probe with connection head form B
(1) Basic type
902120/11
Push-in RTD temperature probes
with stepped sheath
(2) Operating temperature in °C
x 150 -200 to +600 °C
x 402 -50 to +400 °C (standard)
x 415 -50 to +600 °C
(3) Measuring insert
x 1001 1x Pt100 in 3-wire-circuit
x 1003 1x Pt100 in 2-wire circuit
x 1011 1x Pt100 in 4-wire circuit
x 2001 2x Pt100 in 3-wire circuit
x 2003 2x Pt100 in 2-wire circuit
(4) Tolerance class as per DIN EN 60751
x 1 Class B (standard)
x2Class A
(5) Sheath diameter D in mm
x 12 Ø 12 mm stepped down to 9 mm
(6) Nominal length NL in mm (100≤ΝΛ£700)
x 180 180 mm, fitting length (EL) 100 to 140 mm
x 270 270 mm, fitting length (EL) 100 to 230 mm
x 290 290 mm, fitting length (EL) 100 to 250 mm
x 350 350 mm, fitting length (EL) 100 to 310 mm
x 410 410 mm, fitting length (EL) 100 to 370 mm
x 500 500 mm, fitting length (EL) 100 to 460 mm
x ... Specification in plain text (50 mm steps)
(7) Process connection
x 000 without process connection
x 254 Sheath screw-connection G 1/2
(8) Extra codes
x 000 no extra code
x 320 terminal head Form BUZ
x 321 terminal head Form BUZH
x 322 Connection head form BBK
x 330 1x analog transmitter, 4 to 20 mA
2
output, data sheet 70.7030
x 331 1x transmitter programmable output 4to20mA/20to4mA
3
, data sheet 70.7010
x 333 1x analog transmitter, 0 to 10 V
2
output, data sheet 70.7030
x 334 2x analog transmitters, 4 to 20 mA
2
output, data sheet 70.7030
x 335 2x transmitter programmable output 4to20mA/20to4mA
3
, data sheet 70.7010
x 337 2x analog transmitters, 0 to 10 V
2
output, data sheet 70.7030
x 859 1x Wtrans B programmable head transducer with radio transmission, data sheet 70.7060
(1) (2) (3) (4) (5) (6) (7) (8)
Order code ------/ ,...
1
Order example 902120/11 - 402 - 1001 - 1 - 12 - 410 - 000 / 000
1
List extra codes in sequence, separated by commas.
2
Specify measuring range in plain text.
3
Specify measuring range and output signal in plain text.