JUMO GmbH & Co. KG
Delivery address:Mackenrodtstraße 14,
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany
Phone: +49 661 6003-0
Fax: +49 661 6003-607
Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM20 2DY, UK
Phone: +44 1279 635533
Fax: +44 1279 635262
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
8 Technology Boulevard
Canastota, NY 13032, USA
Phone: 315-697-JUMO
1-800-554-JUMO
Fax: 315-697-5867
e-mail: info@jumo.us
Internet: www.jumo.us
Data Sheet 70.6560
2009-12-14/00415638
Block structure
STN color screen
320 x 240 pixels, 27 colors
CPU board
Internal
memory,
256 MByte
Main
memory
SRAM
Setup
interface
Interface for
measurement and
configuration data
Slot II
Slot I
Analog input board 1
7 binary inputs
110 — 240 V AC
+10/-15%, 48 — 63 Hz
30 V AC/DC
48 — 63 Hz
or 20 — ,
6 inputs,
electrically isolated
through optocouplers
6 inputs,
electrically isolated
through optocouplers
Interface for
measurement and
configuration data
RS232 or RS422/485 interface
Ethernet interface
CompactFlash memory card
256 MByte
4 relays (make/
break), 1 open-
collector output
(make/break),
voltage output
24 V/ 50 mA
1 relay (changeover)
I/O board
PSU board
CompactFlash
memory card for
measurement and
configuration data
LON interface
PROFIBUS-DP interface
Interface for
measurement data
Analog input board 1
Key features
k conforms to FDA CFR Part 11
k monitored back-panel cover
k no chart /pens
k presentation of the measurement
data in vertical/horizontal diagrams,
bar graph, numerical, …
k batch reporting
k local availability of the measurement
data stored in RAM
k data records can be saved to a
CompactFlash memory card
k instrument can be configured from the
keypad, via the CompactFlash memory
card or serial interface
k evaluation of the archived data
through the PC evaluation software
k adaptation of the storage cycles to the
individual process through
- normal operation
- event operation
- day-time operation
k report with minimum/maximum/
average values and integrator
k freely programmable inputs for
resistance thermometers,
thermocouples, DC current and
DC voltage
k sampling cycle minimum 125msec
with 12 analog inputs
k PROFIBUS-DP and Ethernet connection
k integrated web server
Approvals
Paperless Recorder for secure
acquisition of FDA-compliant
measurement data
Brief description
Together with its PC software components, this paperless recorder provides a closed sys-
tem for the electronic acquisition, storage and archiving of process data that fulfills the re-
quirements of FDA 21 CFR Part 11.
The presentation is mainly determined by a 5.7" color screen, on which the measurement
data are displayed in different formats (numbers, diagrams, bar graph...).
The integrated Security Manager ensures that only authorized persons can operate the in-
strument, and the integrated Audit-Trail Manager ensures seamless documentation of all
operative actions.
Measurement data are electronically stored and available for evaluation both locally and
on a PC. Front bezel size is 144 mm x 200 mm, maximum mounting depth is 228 mm.
es
Type 706560/
Type 706560/…, stainless steel front
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - Brief description

Page 1/12JUMO GmbH & Co. KGDelivery address:Mackenrodtstraße 14,36039 Fulda, GermanyPostal address:36035 Fulda, GermanyPhone: +49 661 6003-0Fax: +

Seite 2 - Technical data

2009-12-14/00415638Data Sheet 70.6560JUMO GmbH & Co. KG • 36035 Fulda, Germany Page 10/12Potentiometer in 4-wire circuit 1 to 12Voltage input up

Seite 3 - Binary inputs (extra code)

2009-12-14/00415638Data Sheet 70.6560JUMO GmbH & Co. KG • 36035 Fulda, Germany Page 11/12Dimensions (also for stainless steel front)Extra code: un

Seite 4

Data Sheet 70.6560JUMO GmbH & Co. KG • 36035 Fulda, Germany Page 12/122009-12-14/00415638Order detailsLOGOSCREEN es Paperless Recorder for secure

Seite 5

2009-12-14/00415638Data Sheet 70.6560JUMO GmbH & Co. KG • 36035 Fulda, Germany Page 2/12Technical dataInternal analog inputs (channels 1 to 12)The

Seite 6 - Interfaces

2009-12-14/00415638Data Sheet 70.6560JUMO GmbH & Co. KG • 36035 Fulda, Germany Page 3/12Resistance transmitter and potentiometerInput for DC volta

Seite 7 - Data processing

2009-12-14/00415638Data Sheet 70.6560JUMO GmbH & Co. KG • 36035 Fulda, Germany Page 4/12ScreenElectrical dataEnvironmental influencesHousingExtern

Seite 8

2009-12-14/00415638Data Sheet 70.6560JUMO GmbH & Co. KG • 36035 Fulda, Germany Page 5/12Operation andconfigurationOn the recorderThe instrument is

Seite 9 - Connection diagram

JUMO GmbH & Co. KG • 36035 Fulda, Germany Data Sheet 70.6560 Page 6/122009-12-14/00415638Interfacesk Setup interface(fitted as standard)k RS232 in

Seite 10

JUMO GmbH & Co. KG • 36035 Fulda, Germany Data Sheet 70.6560 Page 7/122009-12-14/00415638Data processingData recordingThe measurements of the anal

Seite 11 - 2345678910111

2009-12-14/00415638Data Sheet 70.6560JUMO GmbH & Co. KG • 36035 Fulda, Germany Page 8/12Presentation modes on the recorderGroup managerk 6 groups,

Seite 12 - Order details

2009-12-14/00415638Data Sheet 70.6560JUMO GmbH & Co. KG • 36035 Fulda, Germany Page 9/12Connection diagramRear view with plug-in screw terminalsTe